The coils are subject to various tests on the continuous basis for each and every batch. The standard tests are undertaken as per ECCA & are as follows :

Test undertaken
Standard Data
Remarks
GENERAL
Organic Coating Thickness
Top Coat
20 – 25 micron
zzz
Back Coat
5 - 10 micron
zzz
Specular Gloss @ 60deg
20 – 95 %
zzz

Pencil Hardness

2 H
zzz
Scratch Resistance
1500 gms
zzz
FLEXIBILITY
Reverse Impact
40” / lb
No cracks
Bend Test
2 T
Can go up to 1 T
Erichsen Test
>5mm
No tape off
Cross Hatch
Pass
No tape off
CORROSION RESISTANCE
Salt spray
500Hrs
Polyester
Salt spray
1000 Hrs
PVDF
Humidity
1000Hrs
zzz

QUV weatherometer

1000 Hrs
zzz

Acid Resistance

24 hrs
5% HCL Solution for steel

Alkali resistance

24 hrs
5% NAOH Solution

Double rub test

100 double rub of MEK
zzz
Boiling water
2 hrs
zzz

Testing the LineCupping Test

 

Coil Coating History & Facts  Perfect Coil, Perfect Colour... Perfect Industries